Timed Air Dual Gauge Fully Digital Fluid Dispensing System
sends air into the syringe to
push your material out in measured doses. Includes
an extra digital gauge for measuring
vacuum pressure. This is the dispenser of choice for most adhesive
dispensing applications where it is important to gauge both input and
vacuum in the application.
Click for larger picture. |
|
The fully digital dispenser is equipped with a vacuum mechanism to prevent
material dripping or stringing and the vacuum pressure is clearly shown in a
brightly lit digital gauge. This unit also has a digital timer, which allows the
user to adjust the dispensing time precisely.
Input can signal the
dispenser to dispense by sending a simple I/O signal from a robot or a PLC.
Dispensing and vacuum
pressures display digitally in bright, easy to read numbers on the front of
the unit. The digital display allows the user to monitor either the dispense
time or the pressure measurement and is excellent for monitoring your most
exact process control. This
compact, low cost unit
has
many of the features of far more expensive
dispensing systems and takes up a very small portion of your benchtop.
It is one of our
most popular offline dispensers.
Each IntelliSpense™ Digital Timed
Air Dispenser Package
contains:
-
IntelliSpense™ Digital
Timed Air
Dispenser
-
Power Cord
-
Air Pressure
Connector
-
Barrel Adapter (30/55cc/ml)
-
Needle assortment
startup kit
-
Foot Pedal or
(optional) Finger Switch
-
Universal Power
Supply (115 or 230V).
|
 |
|
Digital Timed Air Dispenser
Setup
-
Connect the Air
Pressure Connector on the back of the system to the nearest air
compressor line.
-
Connect the Foot
Pedal on the back of the system or (optional) Finger Switch on the front
of the system.
-
Fill the
dispensing barrel with adhesive into the
correct barrel adapter.
-
30cc/ml Adapter
(also fits 55cc/ml) is included, 3, 5, and 10cc/ml are
also available, separately.
-
Connect the
chosen syringe adapter to the front of the system.
-
If you are using
the optional Finger Switch, place switch onto the dispensing barrel
or foot pedal, connect the Power
Cord on the back of the system and switch the power on, making sure all
the display and light indicators are working properly.
- Auto-adjusting power supply will accommodate 110V-230V voltage.
-
Select the
appropriate needle from the starter kit and adjust air pressure and
vacuum until you have appropriate size dots or beads.
- Pull out regulator and adjust
air pressure until desired pressure is set; push in and lock to
set the pressure.
|
|

1. Pressure Indicator - Top:
Displays air pressure in the system (psi)
Bottom:
Displays vacuum pressure (psi)
2. Pressure Regulator
- Adjust air pressure; increase with
clockwise and decrease with counter clockwise.
3. Adapter Port -
Connect syringe adapter, press down
and rotate to engage.
4. Vacuum Knob -
Adjust vacuum suck-back pressure in
the syringe to prevent adhesive dripping;
decrease clockwise, increase counter
clockwise.
5. Timer Setting (Up)
- Increase dispensing time setting using timer.
6. Timer Display - Display
dispensing time (0.01sec – 99.99sec).
7. Timer Setting (Down) - Decrease
dispensing time when using timer.
8. Dispensing Indicator - The
indicator will light up during dispensing.
9. Finger Switch Port
- Connect (optional) finger switch.
Insert plug to use.
10. Power Switch - System main power
- switch on, light will
come on.
11. Timer Switch - Switch on and the
power light will light up.
|
Turn off the timer switch; use the foot pedal to activate the
dispenser until the adhesive fills up the
needle and flows out the barrel
to eliminate any trapped air. If the adhesive
does not flow out of the
syringe and through the needle, adjust the pressure or
replace the needle and repeat until satisfactory.
Place the barrel 45 degree to the process object and fit
the needle on top of the dispensing point.
Manual dispensing;
turn off the timer switch and step on the foot pedal
(or press optional finger switch) to activate dispensing;
remove your foot or stop pressing the finger switch
button to stop the dispensing. Timer display will display the
current dispensing time for your reference.
Timed dispensing;
turn on the timer switch and set the timer; step on the foot pedal
(or press optional finger switch) once to
activate one single timed dispense shot,
repeat the process by stepping on the pedal
(or press optional finger switch) again.
Make certain air
supply is clean and dry. Avoid turning barrels
upside down or laying barrel so that material may run through air line
to internal components.
Avoid turning the
vacuum up too high; this may cause the
generation of bubbles in the material or the material to run back into
the system. If the piston inside the barrel is
running up and down during dispensing, it could
mean the material is too thick (high viscosity)
and you will need to replace the piston with our
red piston.
Avoid connecting
to any unregulated air supply exceeding 7
kg/cm2 (100 psi) and 2 kg/cm2 (30 psi) for
the low pressure dispenser.
Use Amyl Alcohol to clean outside surface of the main housing.
If you want to save a syringe barrel
for further use, please take off the needle and replace with
tip cap (optional) or place the barrel on the
barrel stand to help prevent solidification.
|
|
Part # Description
5100805FD
Fully Digital
Timed Air Dispenser with LED Display
with
9991439FS
Finger switch (optional)
*Complete with accessory dispensing kit:
4 30cc/ml syringes, adapter head, selection of needles, tips and
lab stand. Everything you need to get started!
All
Luer Slip and Luer Lock Syringes have
industry-standard Luer Nipples, which are 5/32“ OD and 1/8“ ID.
IntelliSpense Needles will be functional with all
IntelliSpense™
Syringes,
Manual,
Pneumatic or Air Free, as well as any other
brand of standard Luer Lock or Luer Slip Syringe.
1 cc is equivalent to 1 ml. 1
teaspoonful is equivalent to 5 ml (or 5cc).
3 teaspoonfuls are equivalent to 1 tablespoonful. 1 tablespoonful is
equivalent to 15 ml (or 15cc). 1 ounce is equivalent to 30 ml (or 30cc).
|
| |
|