Positive Displacement Valves and Controller
The stroke adjust and micrometer can achieve the same settings, but the Micrometer will display a numerical value for the operator to indicate how far open the valve is. This allows you to develop a QC procedure and periodically check the micrometer to verify it reads the same setting so that they continue to get the same process results. Also if there is more than one valve in line then it will be easy to calibrate all valves to ensure they are set the same.
VALVE ONLY
The 7052000 = Micro-Mini Metering Valve without Micrometer (0.0015-0.012 cc) is intended for use with low to medium viscosity materials. You also require a valve controller and reservoir. Contact IDS with questions.
Intended for high accuracy micro dot deposits.
Availability: Can range from 2 - 4 week build time. Need multiple units? Contact IDS directly for a quote. If you have never used this system with your material, be sure to confirm compatibility. Viscosity Range: Depends On Reservoir - 1 cps - Paste
The 7053000 = Mini Metering Positive Displacement Valve (0.010 - 0.100 cc) is intended for use with low to medium viscosity materials. You also require a valve controller and reservoir. Contact IDS with questions.
Intended for high accuracy micro dot deposits.
Availability: Can range from 2 - 4 week build time. Need multiple units? Contact IDS directly for a quote. If you have never used this system with your material, be sure to confirm compatibility.
VALVE ONLY
The 7052250 Positive Displacement Dispensing Valve (0.0001 - 0.012 cc) is intended for use with low to medium viscosity materials. You also require a valve controller and reservoir. These valves are steel and are not suggested for use with CA (Cyanoacrylate) material. Contact IDS with questions.
Intended for high accuracy micro dot deposits. Customer to specify needle gauge size when ordering (See Gauge Chart In Pictures). Customer may request a Luer Lock Adapter instead. Please note choice in "Note to Seller" box at checkout.
Availability: Can range from 2 - 4 week build time. Need multiple units? Contact IDS directly for a quote. If you have never used this system with your material, be sure to confirm compatibility. Viscosity Range: 1 cps – 50,000 cps
FULL SYSTEM PACKAGE - SHIPPING COST INCLUDED IN PRICE - anywhere in the Continental USA via UPS.
The 7053000PKG is a 7080000 pneumatic pistol grip mounted 7053000 positive displacement dispense valve with regulator assembly, fed by a 30CC or 55CC pneumatic syringe. Includes a sample kit of various needle sizes. Requires 2 regulated compressed air lines, up to 100PSI each with tube compression fittings.
The valve is intended for high accuracy small dot deposits, even if the material thickens over time or changes in thickness from batch to batch. These valves are steel and are not suggested for use with CA (Cyanoacrylate) material.
Availability: From 2 - 4 week build time. Need multiple units? Contact IDS directly for a quote. Note: Know your material! Always confirm compatibility.
The 7055000DAK is a desk top or automation system which includes the pneumatic pistol grip controller to be used manually. Trigger cycles the valve to dispense manually adjusted set volume between 0.1cc to 1.45 cc . This Item Will Require A Tool Balance - approximate weight is 6 pounds. Tool balance not provided. The gun does have a mounted ring to attach to your tool balance.
* 7055000 Positive displacement metering valve, (volume per cycle 0.10 – 1.45cc)
* 7080000 Pneumatic trigger handle to mount & activate valve
* Direct Syringe Mount, 30cc Universal syringe air adapter, luer fluid connection, air regulator & gauge assy., etc.
Contact an IDS representative with questiond. Requires 2 regulated compressed air lines, up to 100psi, with tube fittings. 115V or 230V power supply.
Intended for high accuracy small to large dot deposits, even if the material thickens over time or changes in thickness from batch to batch. These valves are steel and are not suggested for use with CA (Cyanoacrylate) material.
Availability: Can range from 4 week build time. Need multiple units? Contact IDS directly for a quote. If you have never used this system with your material, be sure to confirm compatibility.
The 7055000 positive displacement valve Is intended for dot deposits or filling applications. Contact an IDS representative for a quote on a full system. Requires 2 regulated compressed air lines, up to 100psi, each to function. Also requires a material reservoir to constantly feed material to the valve
Intended for high accuracy small to large dot deposits, even if the material thickens over time or changes in thickness from batch to batch. These valves are steel and are not suggested for use with CA (Cyanoacrylate) material.
Availability: Can range from 2 - 4 week build time. Need multiple units? Contact IDS directly for a quote. If you have never used this system with your material, be sure to confirm compatibility.
Availability: Can range from 2 - 4 week build time. Need multiple units? Contact IDS directly for a quote. If you have never used this system, be sure to confirm compatibility.